{"id":12308,"date":"2025-01-09T12:00:00","date_gmt":"2025-01-09T04:00:00","guid":{"rendered":"https:\/\/www.tosunlux.eu\/?p=12308"},"modified":"2025-01-14T15:51:50","modified_gmt":"2025-01-14T07:51:50","slug":"motor-protection-failures","status":"publish","type":"post","link":"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/","title":{"rendered":"5 errori comuni nella protezione del motore"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_63 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" >Indice dei contenuti<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Attiva\/disattiva la tabella dei contenuti\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Attiva\/disattiva<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Top_5_Motor_Protection_Mistakes_to_Avoid\" title=\"I 5 principali errori da evitare nella protezione del motore\">I 5 principali errori da evitare nella protezione del motore<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#1_Incorrect_Motor_Overload_Protection_Settings\" title=\"#1. Impostazioni errate della protezione da sovraccarico del motore\">#1. Impostazioni errate della protezione da sovraccarico del motore<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#2_Inaccurate_Motor_Overload_Sizing\" title=\"#2. Dimensionamento impreciso del sovraccarico del motore\">#2. Dimensionamento impreciso del sovraccarico del motore<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#3_Failure_to_Install_Three-Phase_Motor_Overload_Protection\" title=\"#3. Mancata installazione della protezione da sovraccarico del motore trifase\">#3. Mancata installazione della protezione da sovraccarico del motore trifase<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#4_Neglecting_Thermally_Protected_Motor_Features\" title=\"#4. Trascurare le caratteristiche del motore con protezione termica\">#4. Trascurare le caratteristiche del motore con protezione termica<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#5_Lack_of_Proper_DC_Motor_Overload_Protection\" title=\"#5. Mancanza di una protezione adeguata contro il sovraccarico del motore CC\">#5. Mancanza di una protezione adeguata contro il sovraccarico del motore CC<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#How_Does_the_Thermo_Protection_on_a_Motor_Work\" title=\"Come funziona la protezione termica di un motore?\">Come funziona la protezione termica di un motore?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Tips_for_Avoiding_Motor_Protection_Mistakes\" title=\"Suggerimenti per evitare errori nella protezione del motore\">Suggerimenti per evitare errori nella protezione del motore<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Regular_Maintenance_and_Inspections\" title=\"Manutenzione e ispezioni regolari\">Manutenzione e ispezioni regolari<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Correct_Installation_of_Overload_Relays\" title=\"Installazione corretta dei rel\u00e8 di sovraccarico\">Installazione corretta dei rel\u00e8 di sovraccarico<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Adhering_to_Manufacturer_Guidelines\" title=\"Rispetto delle linee guida del produttore\">Rispetto delle linee guida del produttore<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Common_Motor_Failure_FAQs\" title=\"Domande frequenti sui guasti comuni del motore\">Domande frequenti sui guasti comuni del motore<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#What_happens_if_a_motor_doesnt_have_overload_protection\" title=\"Cosa succede se un motore non \u00e8 dotato di protezione da sovraccarico?\">Cosa succede se un motore non \u00e8 dotato di protezione da sovraccarico?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#How_do_I_size_a_motor_overload_correctly\" title=\"Come dimensionare correttamente un sovraccarico del motore?\">Come dimensionare correttamente un sovraccarico del motore?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Can_three-phase_motors_run_without_overload_protection\" title=\"I motori trifase possono funzionare senza protezione da sovraccarico?\">I motori trifase possono funzionare senza protezione da sovraccarico?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Are_thermal_overloads_enough_to_protect_motors\" title=\"I sovraccarichi termici sono sufficienti a proteggere i motori?\">I sovraccarichi termici sono sufficienti a proteggere i motori?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#How_often_should_I_inspect_motor_protection_systems\" title=\"Con quale frequenza dovrei ispezionare i sistemi di protezione del motore?\">Con quale frequenza dovrei ispezionare i sistemi di protezione del motore?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/#Common_Motor_Failure_Conclusion\" title=\"Guasto comune del motore: conclusione\">Guasto comune del motore: conclusione<\/a><\/li><\/ul><\/nav><\/div>\n\n<p>Uno degli errori pi\u00f9 comuni nella protezione del motore \u00e8 trascurare le corrette impostazioni di sovraccarico del motore, il che pu\u00f2 portare a guasti delle apparecchiature e costosi tempi di fermo.&nbsp;<\/p>\n\n\n\n<p>Una protezione efficace del motore \u00e8 fondamentale per garantire l&#039;affidabilit\u00e0 e la longevit\u00e0 dei sistemi motore, poich\u00e9 anche piccole sviste possono causare gravi problemi operativi.<\/p>\n\n\n\n<p>In questo articolo esploreremo le insidie pi\u00f9 comuni nella protezione dei motori e come evitarle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Top_5_Motor_Protection_Mistakes_to_Avoid\"><\/span>I 5 principali errori da evitare nella protezione del motore<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Incorrect_Motor_Overload_Protection_Settings\"><\/span>#1. Impostazioni errate della protezione da sovraccarico del motore<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Una protezione da sovraccarico del motore non configurata correttamente \u00e8 un problema frequente che provoca scatti indesiderati o una mancanza di protezione adeguata.&nbsp;<\/p>\n\n\n\n<p>I rel\u00e8 di sovraccarico sono progettati per spegnere il motore quando funziona oltre i limiti di sicurezza per troppo tempo.&nbsp;<\/p>\n\n\n\n<p>Tuttavia, se le impostazioni sono troppo elevate, il motore potrebbe surriscaldarsi prima di scattare, mentre impostazioni eccessivamente conservative causano interruzioni non necessarie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Inaccurate_Motor_Overload_Sizing\"><\/span>#2. Dimensionamento impreciso del sovraccarico del motore<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Il dimensionamento del rel\u00e8 di sovraccarico \u00e8 fondamentale per una protezione efficace del motore. Un rel\u00e8 di sovraccarico troppo piccolo non gestir\u00e0 la corrente di avviamento del motore, causando arresti prematuri.&nbsp;<\/p>\n\n\n\n<p>Al contrario, un rel\u00e8 sovradimensionato non scatter\u00e0 in tempo, causando surriscaldamento e potenziali danni.&nbsp;<\/p>\n\n\n\n<p>Per un dimensionamento corretto \u00e8 necessario tenere conto della corrente a pieno carico del motore, del fattore di servizio e delle condizioni operative.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Failure_to_Install_Three-Phase_Motor_Overload_Protection\"><\/span>#3. Mancata installazione della protezione da sovraccarico del motore trifase<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I motori trifase sono particolarmente vulnerabili agli squilibri di fase o alla monofase, che possono causare un notevole surriscaldamento e stress meccanico.&nbsp;<\/p>\n\n\n\n<p>Senza un&#039;adeguata protezione da sovraccarico, questi motori sono esposti a un rischio maggiore di guasto. Garantire che la protezione di fase sia in atto pu\u00f2 aiutare a rilevare e correggere gli squilibri prima che causino danni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Neglecting_Thermally_Protected_Motor_Features\"><\/span>#4. Trascurare le caratteristiche del motore con protezione termica<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I motori con protezione termica sono dotati di funzioni di sicurezza integrate per evitare il surriscaldamento.&nbsp;<\/p>\n\n\n\n<p>Molti utenti, tuttavia, aggirano o disattivano queste protezioni, sia per mancanza di comprensione, sia per il desiderio di ridurre al minimo i tempi di inattivit\u00e0.&nbsp;<\/p>\n\n\n\n<p>Questo approccio miope aumenta il rischio di bruciatura del motore e di costose riparazioni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Lack_of_Proper_DC_Motor_Overload_Protection\"><\/span>#5. Mancanza di una protezione adeguata contro il sovraccarico del motore CC<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I motori a corrente continua richiedono una protezione specifica contro i sovraccarichi a causa delle loro caratteristiche operative uniche, come l&#039;elevata coppia di spunto e la velocit\u00e0 variabile.&nbsp;<\/p>\n\n\n\n<p>Saltare questa protezione pu\u00f2 causare usura eccessiva, surriscaldamento e guasti prematuri.&nbsp;<\/p>\n\n\n\n<p>L&#039;utilizzo del tipo corretto di dispositivo di protezione garantisce un funzionamento sicuro e previene danni a lungo termine.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Does_the_Thermo_Protection_on_a_Motor_Work\"><\/span>Come funziona la protezione termica di un motore?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>La protezione termica funziona mediante sensori di temperatura che monitorano la temperatura interna del motore.&nbsp;<\/p>\n\n\n\n<p>Quando il motore si surriscalda, questi sensori attivano un rel\u00e8 di protezione che interrompe l&#039;alimentazione, evitando ulteriori danni.&nbsp;<\/p>\n\n\n\n<p>Questo sistema fornisce un meccanismo di sicurezza automatico, proteggendo sia il motore sia le apparecchiature collegate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tips_for_Avoiding_Motor_Protection_Mistakes\"><\/span>Suggerimenti per evitare errori nella protezione del motore<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Regular_Maintenance_and_Inspections\"><\/span>Manutenzione e ispezioni regolari<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I controlli di routine assicurano che tutti i sistemi di protezione funzionino come previsto. Ispezionare i rel\u00e8 di sovraccarico, i sensori di temperatura e il cablaggio per rilevare segni di usura o danni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Correct_Installation_of_Overload_Relays\"><\/span>Installazione corretta dei rel\u00e8 di sovraccarico<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Un&#039;installazione non corretta pu\u00f2 rendere inefficace anche la migliore protezione contro il sovraccarico.&nbsp;<\/p>\n\n\n\n<p>Assicurarsi che i rel\u00e8 siano installati secondo le linee guida del produttore e correttamente calibrati per soddisfare le specifiche del motore.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Adhering_to_Manufacturer_Guidelines\"><\/span>Rispetto delle linee guida del produttore<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Ogni motore ha requisiti unici per le impostazioni di sovraccarico e i dispositivi di protezione. Seguire le raccomandazioni del produttore garantisce una protezione ottimale e riduce al minimo il rischio di errori.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Common_Motor_Failure_FAQs\"><\/span>Domande frequenti sui guasti comuni del motore<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_happens_if_a_motor_doesnt_have_overload_protection\"><\/span>Cosa succede se un motore non \u00e8 dotato di protezione da sovraccarico?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Senza protezione da sovraccarico, il motore rischia di surriscaldarsi, con conseguente guasto dell&#039;isolamento, danni meccanici o addirittura la combustione completa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_do_I_size_a_motor_overload_correctly\"><\/span>Come dimensionare correttamente un sovraccarico del motore?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Il dimensionamento corretto implica l&#039;adattamento del rel\u00e8 alla corrente a pieno carico del motore, tenendo conto delle condizioni operative e del fattore di servizio del motore.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Can_three-phase_motors_run_without_overload_protection\"><\/span>I motori trifase possono funzionare senza protezione da sovraccarico?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Sebbene possibile, il funzionamento senza protezione da sovraccarico espone il motore a potenziali squilibri di fase e surriscaldamento, riducendone notevolmente la durata.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Are_thermal_overloads_enough_to_protect_motors\"><\/span>I sovraccarichi termici sono sufficienti a proteggere i motori?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I sovraccarichi termici forniscono una protezione cruciale ma funzionano meglio in combinazione con altre misure di sicurezza, come <a href=\"https:\/\/www.tosunlux.eu\/it\/blog\/understanding-electrical-short-circuits-types-and-causes\/\">cortocircuito<\/a> protezione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_often_should_I_inspect_motor_protection_systems\"><\/span>Con quale frequenza dovrei ispezionare i sistemi di protezione del motore?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Si consiglia di ispezionare i sistemi di protezione del motore trimestralmente o durante la manutenzione ordinaria per garantirne il corretto funzionamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Common_Motor_Failure_Conclusion\"><\/span>Guasto comune del motore: conclusione<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Una protezione adeguata del motore \u00e8 essenziale per salvaguardare la vostra attrezzatura e garantirne il regolare funzionamento.&nbsp;<\/p>\n\n\n\n<p>Evitando errori comuni come impostazioni di sovraccarico non corrette, dimensionamento impreciso e trascuratezza delle protezioni termiche, puoi prolungare la durata del tuo motore e ridurre al minimo i tempi di fermo.&nbsp;<\/p>\n\n\n\n<p>Una manutenzione regolare e il rispetto delle best practice contribuiranno a mantenere i vostri sistemi efficienti e affidabili.<\/p>\n\n\n\n\n  <style>\n\t\t\t.module {\n\t\t\t\tmargin: 10px 0 30px 0;\n\t\t\t\twidth: 100%;\n\t\t\t\ttext-align: left;\n\t\t\t}\n\t\t\t\/* \u6807\u9898 *\/\n\t\t\t.module .module-title {\n\t\t\t\tfont-size: 18px;\n\t\t\t\tdisplay: flex;\n\t\t\t\talign-items: center;\n\t\t\t}\n\n\t\t\t.module .module-button {\n\t\t\t\tcursor: pointer;\n\t\t\t\tborder: 0px;\n\t\t\t\ttext-align: center;\n\t\t\t\tmargin-left: 10px;\n\t\t\t\tbackground: none;\n\t\t\t}\n\n\t\t\t.module .module-content {\n\t\t\t\tdisplay: none;\n\t\t\t}\n\n\t\t\t.module .module-content.show {\n\t\t\t\tdisplay: block;\n\t\t\t}\n\t\t\t\/* \u7b2c\u4e00\u5757\u5185\u5bb9 *\/\n\t\t\t.module .d1 {\n\t\t\t\twidth: 95%;\n\t\t\t\t\/* \u80cc\u666f\u989c\u8272 *\/\n\t\t\t\tpadding: 1% 2.5% 1% 2.5%;\n\t\t\t\tmargin-top: 3%;\n\t\t\t}\n\t\t\t\/* \u7b2c\u4e8c\u5757\u5185\u5bb9 *\/\n\t\t\t.module .d2 {\n\t\t\t\twidth: 95%;\n\t\t\t\tpadding: 3% 2.5% 3% 2.5%;\n\t\t\t}\n            \/* \u6240\u6709a\u94fe\u63a5\u4e0a\u6587\u5b57 *\/\n            .module .aaa {\n\t\t\t\t\/* \u989c\u8272 *\/\n\t\t\t\tcolor: #00b1cdbd;\n\t\t\t\t\/* \u6587\u5b57\u4e0b\u5212\u7ebf *\/\n\t\t\t\ttext-decoration: underline;\n\t\t\t}\n\t\t\t\/* \u4e0b\u65b9\u659c\u4f53\u6587\u5b57 *\/\n\t\t\t.module .a2 {\n\t\t\t\t\/* \u659c\u4f53 *\/\n\t\t\t\tfont-style: italic;\n\t\t\t}\n\t\t\t\/* \u6240\u6709a\u94fe\u63a5\u4e0a\u6587\u5b57\u60ac\u6d6e\u53d8\u8272 *\/\n\t\t\t.module .aaa:hover {\n\t\t\t\t\/* \u989c\u8272 *\/\n\t\t\t\tcolor: #D3CCFF;\n\t\t\t}\n\t\t<\/style>\n  <div class='module'>\n\t\t\t<div class='module-title' style='font-size: 18px;'>\n\t\t\t\t<!-- \u8fd9\u662f\u6807\u9898 -->\n\t\t\t\tFonti dell&#039;articolo\n\t\t\t\t<button class='module-button'>\n\t\t\t\t\t<svg id='svg-1' style='display:block' t='1710230154863' class='icon' viewbox='0 0 1026 1024'\n\t\t\t\t\t\tversion='1.1' xmlns='http:\/\/www.w3.org\/2000\/svg' p-id='1843' width='18' height='18'>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u5927\u5c0f\u8bf7\u5728width\u548cheight\u4e2d\u6539 -->\n\t\t\t\t\t\t<path\n\t\t\t\t\t\t\td='M511.602721 1023.001027a511.474051 511.474051 0 1 1 360.629164-148.84694 509.476105 509.476105 0 0 1-360.629164 149.845913z m0-941.032335c-109.887003 0-220.772979 41.956856-304.686691 125.870567-167.827423 168.826396-167.827423 441.545958 0 609.373381s440.546985 167.827423 609.373381 0c167.827423-167.827423 167.827423-440.546985 0-609.373381-83.913711-82.914739-194.799687-124.871594-304.68669-124.871595z m332.657927 763.215185z'\n\t\t\t\t\t\t\tfill='#00b1cdbd' p-id='1844'><\/path>\n\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u989c\u8272\u8bf7\u5728fill\u4e2d\u6539 -->\n\t\t\t\t\t\t<path\n\t\t\t\t\t\t\td='M780.326392 552.484859H241.880077a39.95891 39.95891 0 0 1 0-79.91782h538.446315a39.95891 39.95891 0 0 1 0 79.91782z'\n\t\t\t\t\t\t\tfill='#00b1cdbd' p-id='1845'><\/path>\n\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u989c\u8272\u8bf7\u5728fill\u4e2d\u6539 -->\n\t\t\t\t\t\t<path\n\t\t\t\t\t\t\td='M511.602721 822.207503a39.95891 39.95891 0 0 1-39.958911-39.95891V243.802278a39.95891 39.95891 0 1 1 79.917821 0v538.446315a39.95891 39.95891 0 0 1-39.95891 39.95891z'\n\t\t\t\t\t\t\tfill='#00b1cdbd' p-id='1846'><\/path>\n\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u989c\u8272\u8bf7\u5728fill\u4e2d\u6539 -->\n\t\t\t\t\t<\/svg>\n\t\t\t\t\t<svg id='svg-2' style='display:none' t='1710230227147' class='icon' viewbox='0 0 1026 1024'\n\t\t\t\t\t\tversion='1.1' xmlns='http:\/\/www.w3.org\/2000\/svg' p-id='1999' width='18' height='18'>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u5927\u5c0f\u8bf7\u5728width\u548cheight\u4e2d\u6539 -->\n\t\t\t\t\t\t<path\n\t\t\t\t\t\t\td='M511.602721 1023.001027a511.474051 511.474051 0 1 1 360.629164-148.84694 509.476105 509.476105 0 0 1-360.629164 149.845913z m0-941.032335c-109.887003 0-220.772979 41.956856-304.686691 125.870567-167.827423 168.826396-167.827423 441.545958 0 609.373381s440.546985 167.827423 609.373381 0c167.827423-167.827423 167.827423-440.546985 0-609.373381-83.913711-82.914739-194.799687-124.871594-304.68669-124.871595z m332.657927 763.215185z'\n\t\t\t\t\t\t\tfill='#00b1cdbd' p-id='2000'><\/path>\n\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u989c\u8272\u8bf7\u5728fill\u4e2d\u6539 -->\n\t\t\t\t\t\t<path\n\t\t\t\t\t\t\td='M780.326392 552.484859H241.880077a39.95891 39.95891 0 0 1 0-79.91782h538.446315a39.95891 39.95891 0 0 1 0 79.91782z'\n\t\t\t\t\t\t\tfill='#00b1cdbd' p-id='2001'><\/path>\n\t\t\t\t\t\t\t<!-- \u4fee\u6539\u56fe\u6807\u989c\u8272\u8bf7\u5728fill\u4e2d\u6539 -->\n\t\t\t\t\t<\/svg>\n\t\t\t\t<\/button>\n\t\t\t<\/div>\n\t\t\t<div class='module-content'>\n\t\t\t\t<div class='d1' style='background-color:#00b1cdbd'>\n\t\t\t\t\t<!-- \u8fd9\u662f\u6587\u5b57\u7b80\u4ecb -->\n\t\t\t\t\t<span style='font-size:18px'>TOSUNlux utilizza solo fonti di alta qualit\u00e0, tra cui studi sottoposti a revisione paritaria, per supportare i fatti nei nostri articoli. Il nostro impegno per l&#039;accuratezza e l&#039;affidabilit\u00e0 garantisce che i lettori ricevano informazioni ben documentate di cui possono fidarsi.\r\n\t\t\t\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t<ul class='d2'>\n\t\t\t\t\n  <li style='list-style: decimal;font-size:18px;'><a class='aaa a2' target='_blank' href='https:\/\/blog.se.com\/industry\/machine-and-process-management\/2019\/03\/07\/motor-protection-three-common-mistakes-and-how-to-avoid-them\/'>Protezione del motore: tre errori comuni e come evitarli<\/a><\/li>\n  \n  <li style='list-style: decimal;font-size:18px;'><a class='aaa a2' target='_blank' href='https:\/\/www.mes.com.sg\/2023\/11\/28\/ensuring-motor-protection-the-3-common-missteps-to-avoid\/'>Garantire la protezione del motore: i 3 errori pi\u00f9 comuni da evitare<\/a><\/li>\n  \n  <li style='list-style: decimal;font-size:18px;'><a class='aaa a2' target='_blank' href='https:\/\/www.electricaltechnology.org\/2020\/10\/motor-protection-types-faults-protection-devices.html'>Tipi di guasti del motore e dispositivi di protezione<\/a><\/li>\n  \n  <li style='list-style: decimal;font-size:18px;'><a class='aaa a2' target='_blank' href='https:\/\/www.saypro.com.tr\/en\/common-mistakes-in-engine-protection\/'>Errori comuni nella protezione del motore<\/a><\/li>\n  \n\t\t\t\t<\/ul>\n\t\t\t<\/div>\n\t\t<\/div>\n\t\t<script>\n\t\t\tconst moduleButtons = document.querySelectorAll('.module-button');\n\t\t\tconst svg1 = document.getElementById('svg-1');\n\t\t\tconst svg2 = document.getElementById('svg-2');\n\t\t\tfor (const button of moduleButtons) {\n\t\t\t\tbutton.addEventListener('click', function() {\n\t\t\t\t\tconst content = this.parentNode.nextElementSibling;\n\t\t\t\t\tcontent.classList.toggle('show');\n\t\t\t\t\tconst svg = this.querySelector('svg');\n\t\t\t\t\tconst plusPath = svg.querySelector('#plus');\n\t\t\t\t});\n\t\t\t\tsvg1.addEventListener('click', function() {\n\t\t\t\t\tsvg1.style.display = 'none';\n\t\t\t\t\tsvg2.style.display = 'block';\n\t\t\t\t});\n\n\t\t\t\tsvg2.addEventListener('click', function() {\n\t\t\t\t\tsvg2.style.display = 'none';\n\t\t\t\t\tsvg1.style.display = 'block';\n\t\t\t\t});\n\t\t\t}\n\t\t<\/script>","protected":false},"excerpt":{"rendered":"<p>One of the most common mistakes in motor protection is neglecting proper motor overload settings, which can lead to equipment failure and costly downtime.&nbsp; Effective motor protection is vital for ensuring the reliability and longevity of your motor systems, as even minor oversights can result in major operational setbacks. In this article, we\u2019ll explore the common pitfalls in motor protection and how to avoid them. Top 5 Motor Protection Mistakes to Avoid #1. Incorrect Motor Overload Protection Settings Improperly configured motor overload protection is a frequent issue that results in either nuisance tripping or a lack of adequate protection.&nbsp; Overload relays are designed to shut down the motor when it operates beyond its safe limits for too long.&nbsp; However, if the settings are too high, the motor may overheat before tripping, while overly conservative settings cause unnecessary interruptions. #2. Inaccurate Motor Overload Sizing Sizing the overload relay is critical for effective motor protection. An overload relay that is too small won\u2019t handle the motor\u2019s starting current, causing premature shutdowns.&nbsp; Conversely, an oversized relay won\u2019t trip in time, leading to overheating and potential damage.&nbsp; Proper sizing involves factoring in the motor\u2019s full-load current, service factor, and operating conditions. #3. Failure to Install Three-Phase Motor Overload Protection Three-phase motors are particularly vulnerable to phase imbalances or single-phasing, which can result in significant overheating and mechanical stress.&nbsp; Without proper overload protection, these motors face a higher risk of failure. Ensuring that phase protection is in place can help detect and correct imbalances before they cause damage. #4. Neglecting [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12309,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[49],"tags":[],"class_list":["post-12308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>5 Common Mistakes in Motor Protection - TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China<\/title>\n<meta name=\"description\" content=\"Common motor protection mistakes, like incorrect overload sizing or neglecting thermal protection, can lead to motor failure and costly repairs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"5 Common Mistakes in Motor Protection - TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\" \/>\n<meta property=\"og:description\" content=\"Common motor protection mistakes, like incorrect overload sizing or neglecting thermal protection, can lead to motor failure and costly repairs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/\" \/>\n<meta property=\"og:site_name\" content=\"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/TOSUNelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-09T04:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-14T07:51:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"352\" \/>\n\t<meta property=\"og:image:height\" content=\"290\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/person\\\/a775a92fd66d941e4cbb706a83cd3173\"},\"headline\":\"5 Common Mistakes in Motor Protection\",\"datePublished\":\"2025-01-09T04:00:00+00:00\",\"dateModified\":\"2025-01-14T07:51:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/\"},\"wordCount\":841,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/Motor-Protection.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/\",\"name\":\"5 Common Mistakes in Motor Protection - TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/Motor-Protection.jpg\",\"datePublished\":\"2025-01-09T04:00:00+00:00\",\"dateModified\":\"2025-01-14T07:51:50+00:00\",\"description\":\"Common motor protection mistakes, like incorrect overload sizing or neglecting thermal protection, can lead to motor failure and costly repairs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/Motor-Protection.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/Motor-Protection.jpg\",\"width\":352,\"height\":290},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/motor-protection-failures\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"5 Common Mistakes in Motor Protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#website\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\",\"name\":\"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\",\"description\":\"Power Distribution System Supplier\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\"},\"alternateName\":\"TOSUNlux\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\",\"name\":\"TOSUNlux\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/LOGOSYSM.71762f1.png\",\"contentUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/LOGOSYSM.71762f1.png\",\"width\":153,\"height\":55,\"caption\":\"TOSUNlux\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/TOSUNelectric\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/wenzhou-tosun-electric-co.-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/person\\\/a775a92fd66d941e4cbb706a83cd3173\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/www.tosunlux.eu\"],\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/it\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"5 errori comuni nella protezione del motore - Sito ufficiale TOSUNlux - Produttore di interruttori elettrici in Cina","description":"Errori comuni nella protezione del motore, come il dimensionamento errato del sovraccarico o la mancata protezione termica, possono causare guasti al motore e costose riparazioni.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/","og_locale":"it_IT","og_type":"article","og_title":"5 Common Mistakes in Motor Protection - TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China","og_description":"Common motor protection mistakes, like incorrect overload sizing or neglecting thermal protection, can lead to motor failure and costly repairs.","og_url":"https:\/\/www.tosunlux.eu\/it\/blog\/motor-protection-failures\/","og_site_name":"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China","article_publisher":"https:\/\/www.facebook.com\/TOSUNelectric\/","article_published_time":"2025-01-09T04:00:00+00:00","article_modified_time":"2025-01-14T07:51:50+00:00","og_image":[{"width":352,"height":290,"url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"admin","Tempo di lettura stimato":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#article","isPartOf":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/"},"author":{"name":"admin","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/person\/a775a92fd66d941e4cbb706a83cd3173"},"headline":"5 Common Mistakes in Motor Protection","datePublished":"2025-01-09T04:00:00+00:00","dateModified":"2025-01-14T07:51:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/"},"wordCount":841,"publisher":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#organization"},"image":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg","articleSection":["Blog"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/","url":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/","name":"5 errori comuni nella protezione del motore - Sito ufficiale TOSUNlux - Produttore di interruttori elettrici in Cina","isPartOf":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#primaryimage"},"image":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg","datePublished":"2025-01-09T04:00:00+00:00","dateModified":"2025-01-14T07:51:50+00:00","description":"Errori comuni nella protezione del motore, come il dimensionamento errato del sovraccarico o la mancata protezione termica, possono causare guasti al motore e costose riparazioni.","breadcrumb":{"@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#primaryimage","url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg","contentUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/01\/Motor-Protection.jpg","width":352,"height":290},{"@type":"BreadcrumbList","@id":"https:\/\/www.tosunlux.eu\/blog\/motor-protection-failures\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tosunlux.eu\/ru\/"},{"@type":"ListItem","position":2,"name":"5 Common Mistakes in Motor Protection"}]},{"@type":"WebSite","@id":"https:\/\/www.tosunlux.eu\/ru\/#website","url":"https:\/\/www.tosunlux.eu\/ru\/","name":"Sito ufficiale TOSUNlux - Produttore di interruttori elettrici in Cina","description":"Fornitore di sistemi di distribuzione di energia","publisher":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#organization"},"alternateName":"TOSUNlux","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tosunlux.eu\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.tosunlux.eu\/ru\/#organization","name":"TOSUNlux","url":"https:\/\/www.tosunlux.eu\/ru\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/logo\/image\/","url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/01\/LOGOSYSM.71762f1.png","contentUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/01\/LOGOSYSM.71762f1.png","width":153,"height":55,"caption":"TOSUNlux"},"image":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/TOSUNelectric\/","https:\/\/www.linkedin.com\/company\/wenzhou-tosun-electric-co.-ltd\/"]},{"@type":"Person","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/person\/a775a92fd66d941e4cbb706a83cd3173","name":"amministratore","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.tosunlux.eu"],"url":"https:\/\/www.tosunlux.eu\/it\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/posts\/12308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/comments?post=12308"}],"version-history":[{"count":2,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/posts\/12308\/revisions"}],"predecessor-version":[{"id":12359,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/posts\/12308\/revisions\/12359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/media\/12309"}],"wp:attachment":[{"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/media?parent=12308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/categories?post=12308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tosunlux.eu\/it\/wp-json\/wp\/v2\/tags?post=12308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}