{"id":12811,"date":"2025-03-04T15:10:00","date_gmt":"2025-03-04T07:10:00","guid":{"rendered":"https:\/\/www.tosunlux.eu\/?p=12811"},"modified":"2025-03-10T18:06:03","modified_gmt":"2025-03-10T10:06:03","slug":"breaking-capacity-vs-circuit-breaker-ratings","status":"publish","type":"post","link":"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/","title":{"rendered":"Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri: Ayn\u0131 m\u0131d\u0131r?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_63 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" >\u0130\u00e7indekiler<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u0130\u00e7indekiler Tablosunu A\u00e7\/Kapat\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Ge\u00e7i\u015f<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Key_Differences_Between_Breaking_Capacity_and_Circuit_Breaker_Ratings\" title=\"Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Aras\u0131ndaki Temel Farklar\">Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Aras\u0131ndaki Temel Farklar<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Understanding_Circuit_Breaker_Ratings\" title=\"Sigorta Derecelendirmelerini Anlamak\">Sigorta Derecelendirmelerini Anlamak<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Rated_Current_In\" title=\"Anma Ak\u0131m\u0131 (In)\">Anma Ak\u0131m\u0131 (In)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Rated_Voltage_Ue\" title=\"Anma Gerilimi (Ue)\">Anma Gerilimi (Ue)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Rated_Frequency_Hz\" title=\"Anma Frekans\u0131 (Hz)\">Anma Frekans\u0131 (Hz)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Breaking_Capacity_Icu_Ics\" title=\"Kesme Kapasitesi (Icu \/ Ics)\">Kesme Kapasitesi (Icu \/ Ics)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#What_is_Breaking_Capacity\" title=\"K\u0131r\u0131lma Kapasitesi Nedir?\">K\u0131r\u0131lma Kapasitesi Nedir?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Breaking_Capacity_Types\" title=\"Kesme Kapasitesi T\u00fcrleri\">Kesme Kapasitesi T\u00fcrleri<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Measuring_Breaking_Capacity\" title=\"K\u0131r\u0131lma Kapasitesinin \u00d6l\u00e7\u00fclmesi\">K\u0131r\u0131lma Kapasitesinin \u00d6l\u00e7\u00fclmesi<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Why_Breaking_Capacity_Matters_in_Electrical_Safety\" title=\"Elektrik G\u00fcvenli\u011finde Kesme Kapasitesinin \u00d6nemi\">Elektrik G\u00fcvenli\u011finde Kesme Kapasitesinin \u00d6nemi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#How_to_Select_the_Right_Circuit_Breaker_Based_on_Breaking_Capacity\" title=\"Kesme Kapasitesine G\u00f6re Do\u011fru Devre Kesici Nas\u0131l Se\u00e7ilir\">Kesme Kapasitesine G\u00f6re Do\u011fru Devre Kesici Nas\u0131l Se\u00e7ilir<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Step_1_Determine_the_Systems_Short-Circuit_Current\" title=\"Ad\u0131m #1: Sistemin K\u0131sa Devre Ak\u0131m\u0131n\u0131 Belirleyin\">Ad\u0131m #1: Sistemin K\u0131sa Devre Ak\u0131m\u0131n\u0131 Belirleyin<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Step_2_Match_the_Breakers_Breaking_Capacity\" title=\"Ad\u0131m #2: Kesicinin Kesme Kapasitesini E\u015fle\u015ftirin\">Ad\u0131m #2: Kesicinin Kesme Kapasitesini E\u015fle\u015ftirin<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Step_3_Consider_System_Voltage_and_Application\" title=\"Ad\u0131m #3: Sistem Voltaj\u0131n\u0131 ve Uygulamas\u0131n\u0131 Dikkate Al\u0131n\">Ad\u0131m #3: Sistem Voltaj\u0131n\u0131 ve Uygulamas\u0131n\u0131 Dikkate Al\u0131n<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Impact_of_Breaking_Capacity_on_System_Coordination\" title=\"Kesme Kapasitesinin Sistem Koordinasyonu \u00dczerindeki Etkisi\">Kesme Kapasitesinin Sistem Koordinasyonu \u00dczerindeki Etkisi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#FAQs_About_Breaking_Capacity_and_Circuit_Breaker_Ratings\" title=\"Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Hakk\u0131nda SSS\">Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Hakk\u0131nda SSS<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#What_Determines_a_Circuits_Capacity\" title=\"Bir Devrenin Kapasitesini Ne Belirler?\">Bir Devrenin Kapasitesini Ne Belirler?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#What_Happens_if_a_Breakers_Breaking_Capacity_is_Too_Low\" title=\"Bir Kesicinin Kesme Kapasitesi \u00c7ok D\u00fc\u015f\u00fckse Ne Olur?\">Bir Kesicinin Kesme Kapasitesi \u00c7ok D\u00fc\u015f\u00fckse Ne Olur?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#How_is_Breaking_Capacity_of_a_Circuit_Breaker_Calculated\" title=\"Bir Devre Kesicinin Kesme Kapasitesi Nas\u0131l Hesaplan\u0131r?\">Bir Devre Kesicinin Kesme Kapasitesi Nas\u0131l Hesaplan\u0131r?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Is_a_Higher_Breaking_Capacity_Always_Better\" title=\"Daha Y\u00fcksek K\u0131r\u0131lma Kapasitesi Her Zaman Daha M\u0131 \u0130yidir?\">Daha Y\u00fcksek K\u0131r\u0131lma Kapasitesi Her Zaman Daha M\u0131 \u0130yidir?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#How_Often_Should_Circuit_Breakers_Be_Tested_for_Breaking_Capacity\" title=\"Sigortalar Kesme Kapasitesi A\u00e7\u0131s\u0131ndan Ne S\u0131kl\u0131kla Test Edilmelidir?\">Sigortalar Kesme Kapasitesi A\u00e7\u0131s\u0131ndan Ne S\u0131kl\u0131kla Test Edilmelidir?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Breaking_Capacity_vs_Circuit_Breaker_Rating_Conclusion\" title=\"Kesme Kapasitesi ve Devre Kesici Derecelendirmesi: Sonu\u00e7\">Kesme Kapasitesi ve Devre Kesici Derecelendirmesi: Sonu\u00e7<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#Resources\" title=\"Kaynaklar:\">Kaynaklar:<\/a><\/li><\/ul><\/nav><\/div>\n\n<p>Kesme kapasitesi ve devre kesici de\u011ferleri s\u0131kl\u0131kla kar\u0131\u015ft\u0131r\u0131l\u0131r, ancak elektrik sistemlerinde farkl\u0131 ama\u00e7lara hizmet ederler.&nbsp;<\/p>\n\n\n\n<p>Kesme kapasitesi, g\u00fcvenli bir \u015fekilde kesilebilecek maksimum ar\u0131zay\u0131 ifade ederken, devre kesici de\u011ferleri voltaj, ak\u0131m ve <a href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/the-interrupt-capacity-of-circuit-breakers\/\" target=\"_blank\" rel=\"noreferrer noopener\">kesinti kapasitesi<\/a> devre kesiciler.&nbsp;<\/p>\n\n\n\n<p>Do\u011fru kesiciyi se\u00e7mek her ikisinin de anla\u015f\u0131lmas\u0131n\u0131 gerektirir.&nbsp;<\/p>\n\n\n\n<p>Bu k\u0131lavuzda, aralar\u0131ndaki farklar\u0131 ve her ikisinin de elektrik g\u00fcvenli\u011fi a\u00e7\u0131s\u0131ndan neden kritik \u00f6neme sahip oldu\u011funu ele alaca\u011f\u0131z.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Key_Differences_Between_Breaking_Capacity_and_Circuit_Breaker_Ratings\"><\/span>Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Aras\u0131ndaki Temel Farklar<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Bak\u0131\u015f a\u00e7\u0131s\u0131<\/strong><\/td><td><strong>Sigorta Derecelendirmeleri<\/strong><\/td><td><strong>K\u0131r\u0131lma Kapasitesi<\/strong><\/td><\/tr><tr><td>Tan\u0131m<\/td><td>Bir kesicinin elektriksel \u00f6zelliklerinin tam seti.<\/td><td>Maksimum ar\u0131za ak\u0131m\u0131, kesicinin g\u00fcvenli bir \u015fekilde kesebilece\u011fi ak\u0131md\u0131r.<\/td><\/tr><tr><td>\u00d6l\u00e7\u00fcm Birimi<\/td><td>Amper (A) ak\u0131m, Volt (V) voltaj anlam\u0131na gelir.<\/td><td>K\u0131sa devre ak\u0131m\u0131 i\u00e7in kiloamper (kA).<\/td><\/tr><tr><td>Ama\u00e7<\/td><td>Bir kesicinin normal ko\u015fullar alt\u0131nda nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 tan\u0131mlar.<\/td><td>Kesicinin ar\u0131za ko\u015fullar\u0131n\u0131 ele alma yetene\u011fini belirler.<\/td><\/tr><tr><td>\u00d6nemi<\/td><td>Devrelerin do\u011fru boyutland\u0131r\u0131lmas\u0131n\u0131 ve korunmas\u0131n\u0131 sa\u011flar.<\/td><td>K\u0131sa devrelerde hasar\u0131 \u00f6nler ve sistem g\u00fcvenli\u011fini sa\u011flar.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Bu farkl\u0131l\u0131klar\u0131 anlamak, herhangi bir elektrik uygulamas\u0131 i\u00e7in do\u011fru devre kesiciyi se\u00e7meye yard\u0131mc\u0131 olur.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Understanding_Circuit_Breaker_Ratings\"><\/span>Sigorta Derecelendirmelerini Anlamak<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-1024x1024.jpg\" alt=\"TSN3-40\" class=\"wp-image-7801\" width=\"262\" height=\"262\" srcset=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-1024x1024.jpg 1024w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-300x300.jpg 300w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-150x150.jpg 150w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-768x768.jpg 768w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-1536x1536.jpg 1536w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40-12x12.jpg 12w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/05\/TSN3-40.jpg 1600w\" sizes=\"(max-width: 262px) 100vw, 262px\" \/><\/figure>\n<\/div>\n\n\n<p>Bir devre kesicinin derecesi, bir devre kesicinin normal ve ar\u0131za ko\u015fullar\u0131 alt\u0131nda nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 belirleyen bir dizi elektriksel parametredir.<\/p>\n\n\n\n<p>Bu derecelendirmeler, bir kesicinin tasarlanm\u0131\u015f s\u0131n\u0131rlar\u0131 i\u00e7inde etkili bir \u015fekilde \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flar. Temel \u00f6zellikler \u015funlar\u0131 i\u00e7erir:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rated_Current_In\"><\/span>Anma Ak\u0131m\u0131 (In)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Bu, bir kesicinin devre d\u0131\u015f\u0131 kalmadan ta\u015f\u0131yabilece\u011fi s\u00fcrekli ak\u0131md\u0131r. Amper (A) cinsinden \u00f6l\u00e7\u00fcl\u00fcr ve kesici t\u00fcr\u00fcne ba\u011fl\u0131 olarak genellikle 1A ile birka\u00e7 bin ampere kadar de\u011fi\u015fir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rated_Voltage_Ue\"><\/span>Anma Gerilimi (Ue)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Bu, kesicinin g\u00fcvenli bir \u015fekilde \u00e7al\u0131\u015fabilece\u011fi maksimum sistem voltaj\u0131n\u0131 tan\u0131mlar. \u00d6rnekler aras\u0131nda d\u00fc\u015f\u00fck, orta ve y\u00fcksek voltaj uygulamalar\u0131 i\u00e7in 230V, 400V, 11kV ve 33kV bulunur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rated_Frequency_Hz\"><\/span>Anma Frekans\u0131 (Hz)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>\u00c7o\u011fu devre kesici, d\u00fcnya \u00e7ap\u0131ndaki standart AC g\u00fc\u00e7 kaynaklar\u0131yla uyumlu olacak \u015fekilde 50Hz veya 60Hz olarak derecelendirilmi\u015ftir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Breaking_Capacity_Icu_Ics\"><\/span>Kesme Kapasitesi (Icu \/ Ics)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>\u0130\u015fte burada kesme kapasitesi devreye giriyor. Kesicinin kal\u0131c\u0131 hasara u\u011framadan kald\u0131rabilece\u011fi maksimum hata ak\u0131m\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_Breaking_Capacity\"><\/span>K\u0131r\u0131lma Kapasitesi Nedir?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Bir devre kesicinin kesme kapasitesi (kesme kapasitesi olarak da bilinir), k\u0131sa devre ak\u0131mlar\u0131n\u0131 g\u00fcvenli bir \u015fekilde kesme yetene\u011fidir.&nbsp;<\/p>\n\n\n\n<p><a href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/understanding-electrical-short-circuits-types-and-causes\/\" target=\"_blank\" rel=\"noreferrer noopener\">K\u0131sa devre olu\u015ftu\u011funda<\/a>, devre kesiciden b\u00fcy\u00fck bir ak\u0131m dalgas\u0131 ge\u00e7er ve elektrik yang\u0131nlar\u0131n\u0131 veya ekipman hasar\u0131n\u0131 \u00f6nlemek i\u00e7in devrenin kesilmesi gerekir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Breaking_Capacity_Types\"><\/span>Kesme Kapasitesi T\u00fcrleri<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>\u0130ki ana tipte kesme kapasitesi vard\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Nihai K\u0131r\u0131lma Kapasitesi (Icu)<\/strong> \u2013 Bir kesicinin ar\u0131zalanmadan \u00f6nce kesebilece\u011fi en y\u00fcksek ar\u0131za ak\u0131m\u0131.<\/li><li><strong>Hizmet Kesinti Kapasitesi (Ics)<\/strong> \u2013 Kesicinin hasar g\u00f6rmeden tekrar tekrar ne kadar ar\u0131za ak\u0131m\u0131n\u0131 kald\u0131rabilece\u011fini g\u00f6steren Icu y\u00fczdesi.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Measuring_Breaking_Capacity\"><\/span>K\u0131r\u0131lma Kapasitesinin \u00d6l\u00e7\u00fclmesi<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Kesme kapasitesinin ne oldu\u011fu veya kiloamper (kA) cinsinden nas\u0131l \u00f6l\u00e7\u00fcld\u00fc\u011f\u00fc, a\u015fa\u011f\u0131da \u00f6zetlendi\u011fi gibi elektrik sistemine ba\u011fl\u0131 olarak de\u011fi\u015fir:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Ba\u015fvuru<\/strong><\/td><td><strong>K\u0131r\u0131lma Kapasitesi<\/strong><\/td><\/tr><tr><td>Konut Evleri<\/td><td>6kA \u2013 10kA<\/td><\/tr><tr><td>Ticari Binalar<\/td><td>25kA - 50kA<\/td><\/tr><tr><td>End\u00fcstriyel Tesisler<\/td><td>50kA \u2013 100kA<\/td><\/tr><tr><td>Enerji Santralleri<\/td><td>100kA+<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Felaket niteli\u011findeki elektrik ar\u0131zalar\u0131n\u0131 \u00f6nlemek i\u00e7in do\u011fru kesme kapasitesinin se\u00e7ilmesi \u00e7ok \u00f6nemlidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Breaking_Capacity_Matters_in_Electrical_Safety\"><\/span>Elektrik G\u00fcvenli\u011finde Kesme Kapasitesinin \u00d6nemi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Bir devre kesici k\u0131sa devre senaryosu, kesme kapasitesi yetersizse ciddi hasara yol a\u00e7abilir. Baz\u0131 \u00f6nemli riskler \u015funlard\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Elektrik Yang\u0131nlar\u0131<\/strong> \u2013 Y\u00fcksek ar\u0131za ak\u0131mlar\u0131 a\u015f\u0131r\u0131 \u0131s\u0131nmaya yol a\u00e7arak yang\u0131n tehlikesine neden olabilir.<\/li><li><strong>Ekipman Hasar\u0131<\/strong> \u2013 Transformat\u00f6rler, motorlar ve kablolar onar\u0131lamaz hasarlara u\u011frayabilir.<\/li><li><strong>G\u00fcvenlik Tehlikeleri<\/strong> \u2013 A\u015f\u0131r\u0131 ak\u0131m\u0131 kesmede bir sigorta ba\u015far\u0131s\u0131z olursa, elektrik \u00e7arpmas\u0131na veya patlamaya yol a\u00e7abilir.<\/li><\/ul>\n\n\n\n<p>Bir devre kesicinin kesme kapasitesinin sistemin potansiyel ar\u0131za ak\u0131m\u0131yla uyumlu olmas\u0131n\u0131 sa\u011flamak g\u00fcvenlik a\u00e7\u0131s\u0131ndan kritik \u00f6neme sahiptir.<\/p>\n\n\n\n<p>Y\u00fcksek kaliteyi kullanarak <a href=\"https:\/\/www.tosunlux.eu\/tr\/molded-case-circuit-breaker\/\" target=\"_blank\" rel=\"noreferrer noopener\">k\u0131sa devre kesiciler<\/a> en iyi \u00e7\u00f6z\u00fcmd\u00fcr.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Select_the_Right_Circuit_Breaker_Based_on_Breaking_Capacity\"><\/span>Kesme Kapasitesine G\u00f6re Do\u011fru Devre Kesici Nas\u0131l Se\u00e7ilir<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Bir kesici se\u00e7erken \u015fu ad\u0131mlar\u0131 izleyin:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_1_Determine_the_Systems_Short-Circuit_Current\"><\/span>Ad\u0131m #1: Sistemin K\u0131sa Devre Ak\u0131m\u0131n\u0131 Belirleyin<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Sisteminizdeki maksimum k\u0131sa devre ak\u0131m\u0131n\u0131 hesaplamak i\u00e7in trafo kapasitesini, kablo uzunlu\u011funu ve empedans\u0131 kullan\u0131n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_2_Match_the_Breakers_Breaking_Capacity\"><\/span>Ad\u0131m #2: Kesicinin Kesme Kapasitesini E\u015fle\u015ftirin<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Beklenen ar\u0131za ak\u0131m\u0131ndan daha y\u00fcksek kesme kapasitesine sahip bir kesici se\u00e7in.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_3_Consider_System_Voltage_and_Application\"><\/span>Ad\u0131m #3: Sistem Voltaj\u0131n\u0131 ve Uygulamas\u0131n\u0131 Dikkate Al\u0131n<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Konut sistemlerinde 6kA ile 10kA aras\u0131 bir kesici yeterlidir.<\/li><li>End\u00fcstriyel kullan\u0131mlarda 50kA+ gerekebilir.<\/li><\/ul>\n\n\n\n<p>Do\u011fru se\u00e7im, devre kesicinin a\u015f\u0131r\u0131 ko\u015fullar alt\u0131nda devreyi g\u00fcvenli bir \u015fekilde kesebilmesini sa\u011flar.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-1024x683.webp\" alt=\"\" class=\"wp-image-12884\" width=\"479\" height=\"319\" srcset=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-1024x683.webp 1024w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-300x200.webp 300w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-768x512.webp 768w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-1536x1025.webp 1536w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053-18x12.webp 18w, https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5053.webp 2000w\" sizes=\"(max-width: 479px) 100vw, 479px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Impact_of_Breaking_Capacity_on_System_Coordination\"><\/span>Kesme Kapasitesinin Sistem Koordinasyonu \u00dczerindeki Etkisi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Kesme kapasitesi, \u00f6zellikle \u00e7ok seviyeli elektrik \u015febekelerinde sistem koordinasyonunda kritik rol oynar.&nbsp;<\/p>\n\n\n\n<p>Sigortalar sadece ar\u0131za ak\u0131mlar\u0131n\u0131 kesme yeteneklerine g\u00f6re de\u011fil ayn\u0131 zamanda yukar\u0131 ve a\u015fa\u011f\u0131 y\u00f6ndeki koruma cihazlar\u0131yla koordineli \u00e7al\u0131\u015fabilmeleri i\u00e7in se\u00e7ilmelidir.<\/p>\n\n\n\n<p>Uygun koordinasyon, daha k\u00fc\u00e7\u00fck devre kesicilerin daha b\u00fcy\u00fck yukar\u0131 ak\u0131m devre kesicilerinden \u00f6nce devreye girmesini sa\u011flayarak hizmet kesintilerini en aza indirir ve t\u00fcm sistemi korur.&nbsp;<\/p>\n\n\n\n<p>Se\u00e7ici koordinasyon olarak bilinen bu i\u015flem, devrenin yaln\u0131zca ar\u0131zadan etkilenen k\u0131sm\u0131n\u0131n ba\u011flant\u0131s\u0131n\u0131n kesilmesini sa\u011flayarak sistem g\u00fcvenilirli\u011fini art\u0131r\u0131r.<\/p>\n\n\n\n<p>Bir elektrik sistemi tasarlan\u0131rken m\u00fchendisler her seviyedeki ar\u0131za ak\u0131mlar\u0131n\u0131 hesaplamal\u0131 ve sistemin koruma hiyerar\u015fisine uygun kesme kapasitelerine sahip kesicileri se\u00e7melidir.&nbsp;<\/p>\n\n\n\n<p>Bu sayede ar\u0131zalar\u0131n t\u00fcm a\u011f\u0131 etkilemeden izole edilmesi sa\u011flan\u0131yor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQs_About_Breaking_Capacity_and_Circuit_Breaker_Ratings\"><\/span>Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri Hakk\u0131nda SSS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Determines_a_Circuits_Capacity\"><\/span>Bir Devrenin Kapasitesini Ne Belirler?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Bir devrenin kapasitesi voltaja, ak\u0131m talebine ve kald\u0131rabilece\u011fi maksimum k\u0131sa devre ak\u0131m\u0131na ba\u011fl\u0131d\u0131r. Bu fakt\u00f6rler do\u011fru de\u011ferlere sahip bir devre kesicinin se\u00e7ilmesine yard\u0131mc\u0131 olur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Happens_if_a_Breakers_Breaking_Capacity_is_Too_Low\"><\/span>Bir Kesicinin Kesme Kapasitesi \u00c7ok D\u00fc\u015f\u00fckse Ne Olur?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Ar\u0131za ak\u0131m\u0131n\u0131n kesicinin kesme kapasitesini a\u015fmas\u0131 durumunda, kesici devreyi a\u00e7amayabilir ve yang\u0131n veya patlama gibi ciddi elektrik tehlikelerine yol a\u00e7abilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_is_Breaking_Capacity_of_a_Circuit_Breaker_Calculated\"><\/span>Bir Devre Kesicinin Kesme Kapasitesi Nas\u0131l Hesaplan\u0131r?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Kesme kapasitesi, sistemin k\u0131sa devre ak\u0131m\u0131na g\u00f6re \u015fu \u015fekilde hesaplan\u0131r:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXfQeh15B9yDf3rtIXzyTG8SCbbF0ipsBmP0HORCjro1OWLl4PiGrCGpkWf5EI0SdB4exXrS-Ya1aSzf76IF8OOAkh6VV6XP202_KwvETA-8BF5zdszvMa2zCSqdHECUd3kQb1H2HA?key=qYAtXo96UhMBtmX43YMG1lYb\" alt=\"\"\/><\/figure>\n\n\n\n<p>Burada Isc k\u0131sa devre ak\u0131m\u0131, V sistem voltaj\u0131 ve Z toplam sistem empedans\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Is_a_Higher_Breaking_Capacity_Always_Better\"><\/span>Daha Y\u00fcksek K\u0131r\u0131lma Kapasitesi Her Zaman Daha M\u0131 \u0130yidir?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Mutlaka de\u011fil. Daha y\u00fcksek kesme kapasiteli kesiciler daha pahal\u0131d\u0131r ve d\u00fc\u015f\u00fck ar\u0131za ak\u0131m\u0131 sistemleri i\u00e7in gereksiz olabilir. Kesicinin kapasitesini sistemin gereksinimleriyle e\u015fle\u015ftirmek en iyisidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Often_Should_Circuit_Breakers_Be_Tested_for_Breaking_Capacity\"><\/span>Sigortalar Kesme Kapasitesi A\u00e7\u0131s\u0131ndan Ne S\u0131kl\u0131kla Test Edilmelidir?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Her 1-3 y\u0131lda bir yap\u0131lan d\u00fczenli testler, kesicinin ar\u0131za ko\u015fullar\u0131nda do\u011fru \u015fekilde \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flar. Y\u00fcksek g\u00fc\u00e7l\u00fc ekipmanlara sahip end\u00fcstriler testleri daha s\u0131k ger\u00e7ekle\u015ftirmelidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Breaking_Capacity_vs_Circuit_Breaker_Rating_Conclusion\"><\/span>Kesme Kapasitesi ve Devre Kesici Derecelendirmesi: Sonu\u00e7<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Kesme kapasitesi, devre kesici derecelendirmelerinin \u00f6nemli bir par\u00e7as\u0131 olmakla birlikte ayn\u0131 \u015fey de\u011fildir.&nbsp;<\/p>\n\n\n\n<p>Devre kesicilerin kesme kapasitesi, bir devre kesicinin kesebilece\u011fi maksimum ar\u0131za ak\u0131m\u0131n\u0131 ifade ederken, devre kesici de\u011ferleri birden fazla i\u015fletme parametresini tan\u0131mlar.&nbsp;<\/p>\n\n\n\n<p>Her ikisinin de anla\u015f\u0131lmas\u0131, elektrik g\u00fcvenli\u011fini, ekipman\u0131n uygun \u015fekilde korunmas\u0131n\u0131 ve end\u00fcstri standartlar\u0131na uyumu sa\u011flar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Resources\"><\/span>Kaynaklar:<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><a href=\"https:\/\/onccy.com\/understanding-circuit-breaker-short-circuit-breaking-capacity-and-how-to-select-it\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Sigorta K\u0131sa Devre Kesme Kapasitesi ve Nas\u0131l Se\u00e7ilece\u011fi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/www.se.com\/eg\/en\/faqs\/FA228821\/#:~:text=The%20rated%20breaking%20capacity%20(Icu,Icu)%20of%20the%20circuit%20breaker.\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Hizmet kesme kapasitesi nedir?<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/www.linkedin.com\/pulse\/what-breaking-capacity-circuit-breaker-how-choose-bindy-hu\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Devre kesicinin kesme kapasitesi nedir?<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Fundamental_characteristics_of_a_circuit-breaker\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Bir devre kesicinin temel \u00f6zellikleri<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/testbook.com\/electrical-engineering\/rating-of-circuit-breakers\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Devre Kesicinin Derecelendirmesi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/forums.mikeholt.com\/threads\/difference-between-short-circuit-rating-and-ultimate-breaking-rating-icu.2558753\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">K\u0131sa devre derecesi ile Nihai kesme derecesi (ICU) aras\u0131ndaki fark<\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Breaking capacity and circuit breaker ratings are often confused, but they serve different purposes in electrical systems.&nbsp; Breaking capacity refers to the maximum fault that can safely interrupt, while circuit breaker ratings cover multiple specifications like voltage, current, and interrupting capacity of circuit breakers.&nbsp; Selecting the correct breaker requires an understanding of both.&nbsp; In this guide, we\u2019ll break down their differences and why both are critical for electrical safety. Key Differences Between Breaking Capacity and Circuit Breaker Ratings Aspect Circuit Breaker Ratings Breaking Capacity Definition The complete set of electrical specifications of a breaker. The maximum fault current is the one the breaker can safely interrupt. Unit of Measurement Amperes (A) for current, Volts (V) for voltage. Kiloamperes (kA) for short-circuit current. Purpose Defines how a breaker operates under normal conditions. Determines the breaker&#8217;s ability to handle fault conditions. Importance Ensures correct sizing and protection for circuits. Prevents damage during short circuits and ensures system safety. Understanding these differences helps in selecting the right circuit breaker for any electrical application. Understanding Circuit Breaker Ratings A circuit breaker rating is a set of electrical parameters that determine how a breaker operates under normal and fault conditions. These ratings ensure that a breaker functions effectively within its designed limits. The key specifications include: Rated Current (In) This is the continuous current a breaker can carry without tripping. It is measured in amperes (A) and typically ranges from 1A to several thousand amperes, depending on the breaker type. Rated Voltage (Ue) This defines the maximum system voltage at [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12883,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[209],"tags":[],"class_list":["post-12811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-breaker"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same? | TOSUNlux<\/title>\n<meta name=\"description\" content=\"Confused about breaking capacity vs. circuit breaker ratings? Tosunlux explains their roles in electrical protection. Discover more inside!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same? | TOSUNlux\" \/>\n<meta property=\"og:description\" content=\"Confused about breaking capacity vs. circuit breaker ratings? Tosunlux explains their roles in electrical protection. Discover more inside!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/\" \/>\n<meta property=\"og:site_name\" content=\"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/TOSUNelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-04T07:10:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-10T10:06:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/person\\\/a775a92fd66d941e4cbb706a83cd3173\"},\"headline\":\"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same?\",\"datePublished\":\"2025-03-04T07:10:00+00:00\",\"dateModified\":\"2025-03-10T10:06:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/\"},\"wordCount\":1094,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/DSC_5057.webp\",\"articleSection\":[\"Circuit Breaker\"],\"inLanguage\":\"tr\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/\",\"name\":\"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same? | TOSUNlux\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/DSC_5057.webp\",\"datePublished\":\"2025-03-04T07:10:00+00:00\",\"dateModified\":\"2025-03-10T10:06:03+00:00\",\"description\":\"Confused about breaking capacity vs. circuit breaker ratings? Tosunlux explains their roles in electrical protection. Discover more inside!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/DSC_5057.webp\",\"contentUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/DSC_5057.webp\",\"width\":2000,\"height\":1334},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/blog\\\/breaking-capacity-vs-circuit-breaker-ratings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#website\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\",\"name\":\"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China\",\"description\":\"Power Distribution System Supplier\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\"},\"alternateName\":\"TOSUNlux\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#organization\",\"name\":\"TOSUNlux\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/LOGOSYSM.71762f1.png\",\"contentUrl\":\"https:\\\/\\\/www.tosunlux.eu\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/LOGOSYSM.71762f1.png\",\"width\":153,\"height\":55,\"caption\":\"TOSUNlux\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/TOSUNelectric\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/wenzhou-tosun-electric-co.-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tosunlux.eu\\\/ru\\\/#\\\/schema\\\/person\\\/a775a92fd66d941e4cbb706a83cd3173\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/www.tosunlux.eu\"],\"url\":\"https:\\\/\\\/www.tosunlux.eu\\\/tr\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri: Ayn\u0131 m\u0131d\u0131r? | TOSUNlux","description":"Kesme kapasitesi ile devre kesici derecelendirmeleri aras\u0131nda kafan\u0131z m\u0131 kar\u0131\u015ft\u0131? Tosunlux, elektrik korumas\u0131ndaki rollerini a\u00e7\u0131kl\u0131yor. \u0130\u00e7eride daha fazlas\u0131n\u0131 ke\u015ffedin!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/","og_locale":"tr_TR","og_type":"article","og_title":"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same? | TOSUNlux","og_description":"Confused about breaking capacity vs. circuit breaker ratings? Tosunlux explains their roles in electrical protection. Discover more inside!","og_url":"https:\/\/www.tosunlux.eu\/tr\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/","og_site_name":"TOSUNlux Official Site - Electrical Circuit Breaker Manufacturer in China","article_publisher":"https:\/\/www.facebook.com\/TOSUNelectric\/","article_published_time":"2025-03-04T07:10:00+00:00","article_modified_time":"2025-03-10T10:06:03+00:00","og_image":[{"width":2000,"height":1334,"url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp","type":"image\/webp"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Yazan:":"admin","Tahmini okuma s\u00fcresi":"6 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#article","isPartOf":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/"},"author":{"name":"admin","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/person\/a775a92fd66d941e4cbb706a83cd3173"},"headline":"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same?","datePublished":"2025-03-04T07:10:00+00:00","dateModified":"2025-03-10T10:06:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/"},"wordCount":1094,"publisher":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#organization"},"image":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp","articleSection":["Circuit Breaker"],"inLanguage":"tr"},{"@type":"WebPage","@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/","url":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/","name":"Kesme Kapasitesi ve Devre Kesici Derecelendirmeleri: Ayn\u0131 m\u0131d\u0131r? | TOSUNlux","isPartOf":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#primaryimage"},"image":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp","datePublished":"2025-03-04T07:10:00+00:00","dateModified":"2025-03-10T10:06:03+00:00","description":"Kesme kapasitesi ile devre kesici derecelendirmeleri aras\u0131nda kafan\u0131z m\u0131 kar\u0131\u015ft\u0131? Tosunlux, elektrik korumas\u0131ndaki rollerini a\u00e7\u0131kl\u0131yor. \u0130\u00e7eride daha fazlas\u0131n\u0131 ke\u015ffedin!","breadcrumb":{"@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#primaryimage","url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp","contentUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2025\/03\/DSC_5057.webp","width":2000,"height":1334},{"@type":"BreadcrumbList","@id":"https:\/\/www.tosunlux.eu\/blog\/breaking-capacity-vs-circuit-breaker-ratings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tosunlux.eu\/ru\/"},{"@type":"ListItem","position":2,"name":"Breaking Capacity vs. Circuit Breaker Ratings: Are They The Same?"}]},{"@type":"WebSite","@id":"https:\/\/www.tosunlux.eu\/ru\/#website","url":"https:\/\/www.tosunlux.eu\/ru\/","name":"TOSUNlux Resmi Sitesi - \u00c7in&#039;de Elektrik Sigortas\u0131 \u00dcreticisi","description":"G\u00fc\u00e7 Da\u011f\u0131t\u0131m Sistemi Tedarik\u00e7isi","publisher":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#organization"},"alternateName":"TOSUNlux","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tosunlux.eu\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/www.tosunlux.eu\/ru\/#organization","name":"TOSUNlux","url":"https:\/\/www.tosunlux.eu\/ru\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/logo\/image\/","url":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/01\/LOGOSYSM.71762f1.png","contentUrl":"https:\/\/www.tosunlux.eu\/wp-content\/uploads\/2022\/01\/LOGOSYSM.71762f1.png","width":153,"height":55,"caption":"TOSUNlux"},"image":{"@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/TOSUNelectric\/","https:\/\/www.linkedin.com\/company\/wenzhou-tosun-electric-co.-ltd\/"]},{"@type":"Person","@id":"https:\/\/www.tosunlux.eu\/ru\/#\/schema\/person\/a775a92fd66d941e4cbb706a83cd3173","name":"y\u00f6netici","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75eeae9adbd42fdf679c24104222466e12c5914b74822c713229c94e98ed4d2f?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.tosunlux.eu"],"url":"https:\/\/www.tosunlux.eu\/tr\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/posts\/12811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/comments?post=12811"}],"version-history":[{"count":5,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/posts\/12811\/revisions"}],"predecessor-version":[{"id":12912,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/posts\/12811\/revisions\/12912"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/media\/12883"}],"wp:attachment":[{"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/media?parent=12811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/categories?post=12811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tosunlux.eu\/tr\/wp-json\/wp\/v2\/tags?post=12811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}